Basic Info.
Type
Linear Heat Detector
Certifications
FM, UL, Atex/Iecex, CE, Eac
Operating Ambient Temp.
-45 Degree C - +60 Degree C
Alarm Temp.
68c/88c/105c/138c/180c
Transport Package
Cartons
Product Description
MS1000 Series ---Digital Type Linear Heat Detection System Compared with other kind of detectors, MS1000 Digital Linear Heat Detector provides a very-early alarm detecting function to the protected environment, the detector can be known as an intelligent "switch" type detector. The polymers between the two conductors will break down at specific fixed temperature allowing the conductors contact, the shot circuit will intimate the alarm. The detector has a continuous sensitivity. The sensitivity of linear heat detector will not be influenced by the environment temperature changing and the length of detection cable using. It does not need to be adjusted and compensation. The detector can transfer both alarm and fault signals to control panels normally with 24VDC or without 24VDC.
MS1000 Linear Heat Detection(abbr LHD) System Consists:
a. LHD Cable
b. Control Unit
c. End of Line Unit (EOL)Box
LHD Cable
1. Classification
Conventional Type This Type of LHD cable is the most widely used indoor used with strong stability.
CR/OD Type CR/OD Type not only has good UV resistance and good weather resistance, strongly recommended for outdoor using even under bad weather conditions, but also with high performance of acid resistant, alkali-resistant, salt spray resistant.
EP Type Explosion Proof Type, two main application environments: harsh EMI environment and explosive hazardous environment. The outer jacket of this type is protected by woven metal mesh with good performance of anti-EMI and eliminating the surface static of the LHD cable. We can us this type LHD cable in explosive hazardous environment with safety fence. During the installation, please make grounding connection of the woven metal mesh. Used in harsh EMI environment, single end grounding connection or double ends grounding connection should be specified after analysis of the interference sources.
2. Structure Inter twisting two rigid metallic conductors which are covered by NTC heat sensitive material, with insulative bandage and outer jacked, here comes the Digital Type LHD Cable of P.T.S, and the different model numbers depend on the variety of materials of outer jacket to meet different special environments.
3. Features and benefits
Industrial safety design
Electrical interface with low power consumption design
Real-time monitoring
Working with 24VDC supply or without 24VDC supply
Fast response time
No alarm temperature compensation needed
Compatible to any kind fire alarm system
Alarm temperatures: 68ºC,88ºC,105ºC,138ºC,180ºC
Model | MS1000 68ºC | MS1000 88ºC | MS1000 105ºC | MS1000 138ºC | MS1000 180ºC |
| MS1000 CR /OD 68ºC | MS1000 CR /OD 88ºC | MS1000 CR /OD 105ºC | MS1000 CR /OD 138ºC | MS1000 CR /OD 180ºC |
Parameter | MS1000 EP 68ºC | MS1000 EP 88ºC | MS1000 EP 105ºC | MS1000 EP 138ºC | MS1000 EP 180ºC |
Alarm Temperature | 68ºC | 88ºC | 105ºC | 138ºC | 180ºC |
Ambient Temperature (Max) | 45ºC | 60ºC | 75ºC | 93ºC | 121ºC |
Ambient Temperature (Min) | -55ºC for MS1000-CR/OD | -55ºC for MS1000-CR/OD | -55ºC for MS1000-CR/OD | -55ºC for MS1000-CR/OD | -55ºC for MS1000-CR/OD |
-40ºC for MS1000/MS1000-EP | -40ºC for MS1000/MS1000-EP | -40ºC for MS1000/MS1000-EP | -40ºC for MS1000/MS1000-EP | -40ºC for MS1000/MS1000-EP |
Storage Temperature | UP TO 50ºC | UP TO 50ºC | UP TO 50ºC | UP TO 50ºC | UP TO 50ºC |
Alarm Deviation | ±3ºC | ±5ºC | ±5ºC | ±5ºC | ±8ºC |
Alarm Response Time (s) | 10 (Max) | 10 (Max) | 15 (Max) | 20 (Max) | 20 (Max) |
Control Unit & EOL Unit
1. MS1000-I Control Unit Control Unit MS1000-I is used for MS1000, MS1000 CR/OD and MS1000 EP digital type LHD cable. MS1000 is a digital type LHD cable with comparatively simple output signal, the control unit and EOL box are easy to install and operate.
2. Technical parameters
Operating Voltage: 24VDC
Allowed Voltage Range: 16VDC-28VDC
Operating Current : Standby Current: ≤20mA Alarm Current: ≤30mA Fault Current: ≤25mA
Operating environment: Temperature:-45ºC--+60ºC
Relative humidity: 95%
Aluminum alloy Shell
IP Rating: IP66
Dimensions: 90mm×85mm×52mm(H×W×Depth)
MS1000-P
1. EOL Box EOL Box for MS1000, MS1000 CR/OD and MS1000 EP digital type LHD cable.
2. Technical parameters
Operating Voltage: No Electronics
Operating environment: Temperature:-45ºC--+60ºC
Relative humidity: 95%
Aluminum alloy Shell
IP Rating: IP66
Dimensions: 90mm×85mm×52mm(H×W×Depth)
International Honors and Quaifications
Address:
Room 546, Building Youcheng, North Tucheng West Road, Chaoyang district, Beijing
Business Type:
Manufacturer/Factory
Business Range:
Electrical & Electronics, Industrial Equipment & Components, Instruments & Meters, Security & Protection
Management System Certification:
ISO 9001, ISO 14001, OHSAS/ OHSMS 18001
Company Introduction:
P. T. Security Technology Co., Ltd. (simplified as P. T. S) is a leading manufacturer of Linear Heat Detection System. P. T. S aims to become a global leader in Linear Heat Detection System. P. T. S has been developing and manufacturing highly advanced linear heat detector products over 20 years.
In the year of 1994, P. T. S designed and applied the first Linear Heat Detection System for Engineering Application and laid the foundation for Linear Heat Detection system.
In the year of 2012, P. T. S was organization re-structured, and employed more experienced technical professions and scholars, who have been working in fire industry more than 10 years.
In the year of 2013, Beijing P. T. S was established for overseas market development, sales, and service.
In the year of 2014, P. T. S was certified to ISO9001: 2008.
In the year of 2015, P. T. S was approved by Factory Mutual Laboratories (FM approvals).
In the year of 2019, P. T. S was approved by Underwriters Laboratories Inc (UL approvals).